5 Must-Know Fire Door Inspection Tools for Your Property

Fire safety is a major concern for property owners and managers and fire door inspections are crucial for evaluating how well a fire door contains smoke and flames.

Fundamentally, trained experts utilise fire door inspection tools to pinpoint minute gaps and identify potential weaknesses within the door. Experts use these tools to assess various components of the fire door such as gaps, seals, frames, hinges and hardware.

Even though these tools are of vital importance, many fail to use them effectively and struggle to conduct successful fire door inspections.

That’s why, in this article, we explore the top 5 fire door inspection tools and understand how they help experts in fire door inspection.

1. Fire Door Gap Gauge

A fire door gap gauge is a specialised tool used to measure the gaps between the fire door and its frames. Given that these gaps play a crucial role in preventing the spread of fire and smoke, this tool ensures that gaps are within the prescribed limits. 

If the gaps are too large, fire and smoke can slip through easily, causing the door to be less effective during an emergency. By using a fire door gap gauge, inspectors accurately measure and evaluate the openings of these gaps to make sure the fire door is properly aligned. 

Moreover, minimising gaps around the door prevents the progression of fire and smoke without letting it infiltrate adjacent spaces, thereby allowing time for people to evacuate in case of an emergency. 

2. Thermal Imaging Camera 

The use of thermal imaging cameras enhances fire safety, as they play a pivotal role in the early detection, assessment and response of any issues. This camera helps experts identify damaged or deteriorated components within the fire door structure. Furthermore, they also reveal heat leaks around the door frame, seals or hinges.  

Since these cameras operate based on fluctuating temperatures, they enable safety professionals to identify potential safety hazards in the early stages, often before flames appear. Especially in situations where smoke arises first, this fire door inspection tool allows responders to navigate through low visibility to determine the location of the fire. 

By detecting areas with elevated temperatures, experts can gauge smouldering materials that might reignite the spread of fire. This, in turn, helps in making decisions regarding the prevention of fires and determining the strategies to combat them. 

3. Smoke Pen

As a part of a comprehensive fire door inspection checklist, a smoke pen is a tool that emits a visible stream of smoke to identify gaps, leaks and other vulnerabilities around a door. 

During a fire door inspection, a smoke pen determines areas of concern from where smoke could infiltrate, compromising the integrity of containment systems. Through this smoke pen, experts emit harmless smoke towards door frames, windows, or latches. If the smoke is drawn into a building component, it indicates the presence of a gap that might allow the fire to spread.

This fire door inspection tool helps experts identify areas that either need to be sealed or repaired to maintain and enhance the fire-resistant qualities of the components. 

4. Flashlight 

Another important fire door inspection tool is a flashlight – an indispensable device that enhances visibility and facilitates a comprehensive study of critical components.

In dimly lit areas or power outages, a flashlight provides light that helps experts thoroughly examine door edges, frames, latches, hinges, and thresholds to thoroughly check for defects. Moreover, it helps in scrutinising hardware malfunctions related to door closers or panic hardware. 

Furthermore, by casting light on the components, safety experts can address signs of wear and tear or improper installation. This proactive approach with regular inspection helps maintain functionality, ultimately contributing to overall fire safety. 

5. Label Verifier

Another useful tool for the fire door inspection checklist is the label verifier. It is a tool that validates the accuracy of labels affixed to the fire door. These labels highlight information such as fire rating, manufacturer, and installation dates. 

During fire door inspections, labels on the fire door allow inspectors to identify the quality of the door to ensure that it matches its designated fire rating. Thereby preventing any misinterpretations that could compromise the door’s ability to withstand fire. 

By cross-referencing the label’s data, inspectors ensure that these doors comply with safety standards to offer a sustainable living environment for residents and property owners. 

Choose Block Maintenance For Professional Fire Door Inspections

In this blog, we’ve explored how experts use fire door inspection tools and collaboratively uphold the integrity of fire and containment systems. While these are tools are can be used by property managers after some training, it is best to leave it in the hands of the professionals.

That’s where we come in.

With a proven track record of excellence and a dedicated team of experts, we prioritise safety above all else. By choosing us for your property’s fire door inspections, you’re not only safeguarding lives and the condition of your property but also getting a professional service that leaves no room for compromise.

At Block Maintenance, our goal is to use cutting-edge fire door inspection tools to ensure absolute safety compliance. What’s more, along with fire door inspections, we also offer services like access control systems, planned property maintenance, and reactive property maintenance

To learn more about our services, click here or reach out to us now!